- Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Driver Windows 7
- Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Driver Updater
- Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Drivers
Use the dropdown menus below to find the drivers and downloads you want. You can also search by product or keyword. Lumidigm drivers can be found in the Lumidigm Developer Center. If you do not know your Honeywell device model name, this unique ID will come to your aid. To find the required pnp id, go to Computer management menu and right mouse click on a Properties button. You may find this pnpid in such archives as HSM USB Serial Driver r1.19-WHQL.zip, HSM USB Serial Driver r1.12.zip.
- Run serial ports in immediate mode; Range checking; Changes made in 4.4.0.12: Fixed - Spurious timeout when running multiple cubes in ACB mode Fixed - AI-224 calibration and ACB; Changes made in 4.2.0.5: SL-504 - Support added for new SL-604 layer; CT-601 - Implemented new Timed Period Pulse Measurement mode (TPPM) AI-217 - Set correct.
- AnyDATA WCDMA HSU Serial 2 (NMEA) Device (PID 6292) AnyDATA WCDMA HSU Serial 2 (NMEA) Device (PID 6294) AnyDATA WCDMA HSU Serial 3 (AUX) Device (PID 6294).
UEIDAQ Framework library uses the same API to access any devices from PowerDNA Distributed Ethernet I/O families. Using UEIDAQ Framework library dramatically cuts the amount of code needed to perform data acquisition and control tasks. UEI supports all 32/64 bit versions of Windows up to the most current Windows 10.
The UEIDAQ Framework provides a set of C++ classes to easily interface your C++ programs with UEI data acquisition devices. The UEIDAQ Framework also comes with an ANSI-C API.
Instantly download Windows software and drivers for PowerDNA/DNR hardware from UEI. Includes UEIDAQ Framework library, which includes support for the following:
- VisualBASIC 6
- VB.NET
- LabVIEW
- MATLAB
- LabWindows/CVI
- OPC Server
- Excel
- .NET
- C#
- C/C++
- Borland Delphi
- Borland C++ Builder
- INtime
- ActiveX
What’s new in Version 4.10.1.20:
- Added support for DIO-403 inputs in RTVMAP acquisition mode.
Introduced in 4.10.1.14:
- Added support for new chassis DNR-MIL-6.
Introduced in 4.10.0.12:
- Support for Python 3.8.
Introduced in 4.10.0.43:
- Supporting Windows XP/NT and later, including Windows 10.
- Support up to Visual Studio 2017.
Introduced in 4.10.0.11:
Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Driver Windows 7
- Support for Visual Studio 2017.
- Support for 1588 synchronization for -02 and -03 CPU (PTP hardware support).
- Added directory for low-level synchronization examples
- Added support for timestamp first in channel list (useful for correlating timestamps)
- Added support for FIFO overflow recovery (flag DQ_VMAP_FIFO_CLR_ON_OVF added).
- Added support for asynchronous RTVMAP and asynchronous RTDMAP (examples in SampleADmap* and SampleAVmap*).
- Support for offline conversion, no active connection needed to IOM (example code in SampleVMap207OFL).
- Added function DqSupportedModes to determine which acquisition modes are supported for each board (refer to SampleGetDevInfo).
- Support for new ARM SoloX processor.
- Added new network conversion functions to handle endianness based on CPU (DqNtohx, DqHtonx).
- Example code cleanup: use Chk4Err for function returns, ChkOpsMode to start from known state, etc.
Introduced in 4.8.0.18:
- Support for rugged military style DNA-MIL and DNR-MIL
- Framework support for Visual Studio 2013
- Support for I/O layers AI-248, AO-318, AO-364, DIO-449 and DIO-463
- New 'Asynchronous VMAP' operating mode
Introduced in 4.6.0.41:
- AI-222 suport
- Enhanced AI-212 support
- AI-201 timestamp channel
- Added AI-222, AI-248 and DIO-449 examples
- Various enhancements and bug fixes
Introduced in 4.6.0.12:
- Improved IRIG-650 timestamps
- Bugfixes to DNX-AI-201, 207/208 settling time parameter and 224 ACB
- Improved DNcx-AI-201/217 timestamp, AI-218 DIO write, and 212
- Improved support for DNx-AI-364
- Improvements to DNx-AI-403 async edge detection and 449
- Bugfixes to 448 ACB and setlevels and improvement of aggregate rate
- Bugfixes to CAN-503 Williamsburg library
- Bugfixes to 601 PWM, 604 messaging mode
- Bugfixes to MIL-1553, improvements, and new samples
Introduced in 4.6.0.4:
- Full support for AI-212, AI-218 and AI-228
- Preliminary support for AO-364
- Bug fixes
Changes made in 4.4.0.38:
- Run serial ports in immediate mode
- Range checking
Changes made in 4.4.0.12:
- [Fixed] - Spurious timeout when running multiple cubes in ACB mode
- [Fixed] - AI-224 calibration and ACB
Changes made in 4.2.0.5:
- SL-504 - Support added for new SL-604 layer
- CT-601 - Implemented new Timed Period Pulse Measurement mode (TPPM)
- AI-217 - Set correct default gain value.
- DIO-401_4_5_6 - Implemented asynchronous events upon edge detection on input lines.
- DIO-448 - Fix macro for single ended channels
- 1553-708 - assignment of FIFO function for 1553-708 option changed so if one 1553-708 is in the system the functions will not be changed globally and affect all 1553 in the system
- AI-255 - number of DC/DC required was calculated based on V while these DC/DC produce +/-V. This way we had excessive voltage on the op amps rails and dissipated it as waste heat. The voltage level to use extra DC/DC are converted into Vpp voltage in uV.
- ARINC-429-566 - DQ_VMAP_RQSIZE_SZ processing is added to read_fifo_566() and write_fifo_566()
- Debug log wraparound and position reporting is added
- SL-508 - fix to allow 29.5Mhz baseclock for -892 option.
- Fixed very old bug that prevents allocating the same DMAP more than 256 times. (This would happen for example when alternately creating/destroying two different DMAPS.)
- SL-508: fixed baud rate error that was prevalent at higher baud rates
- AI-217: code to accommodate the needs of UEI's calibration department. No functional difference to the user.
- changed the default data filtering for pt-pt and DMAP modes to be in a more useful range.
- MIL-1553: EV553_RT_CUST_LUT us implemented in drv_553.c for advanced 1553 customers
- Custom pSL553CUST_LUT job for advanced 1553 customers - replace TX data of RT/SA upon receiving a predefined set of words in RX area
- ARINC-708: BE and IFF printing is added
- Big-endian/low-endian switch is added for TX and RX of ARINC-708 implementation.
- SL-501/508: Implemented new mode that allows setting the parity bit independently on each byte sent over serial port.
- ...and additional bug fixes
Changes made since PowerDNA 3.8.0.59
- Support for 64 bits editions of Windows XP/Vista/7
- Full support for new layer AO-358
- Full support for new layer 1553-553 (MIL-1553)
- Full support for new layer PC-91x.
- New asynchronous operating mode.
Changes made since PowerDNA 3.8.0.55
- Change ARP to prohibit packet queuing
- Filter out broadcast UPD packets (i.e. NetBios)
- Keep buffer allocated until IOCTL task finishes processing it
- Insert check for correct format of IOCTL packets
- Properly free packets on IOCTLR re-request
- Increased pbuff size to avoid double allocations network buffer
Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Driver Updater
Changes made since PowerDNA 3.8.0.53
- Add AO regeneration for L3
Changes made since PowerDNA 3.8.0.30
- [Fixed] - DIO-404 ACB write
Changes made since PowerDNA 3.8.0.26
- [Fixed] - AI-211 PtByPt UeiDaqStopSession.vi doesn't close session
- [Fixed] - time stamp reset issue in mpc5200 Ethernet firmware
- [Fixed] - Add CPU logic revision to devtbl -l and HW Info Build completed:
- [Fixed] - Add firmware build number to HW info
Changes made since PowerDNA 3.8.0.19
Download Anydata Wcdma Hsu Serial 2 (nmea) Device (pid 6292) Drivers
- AO-308/332/333 DIO-4xx had a glitch on the output because of the bad MTU controller settings.
- AI-254 4-wire external excitation mode ratiometric measurement fixed - use (signed)Sa/(signed)Sb provides proper position reading
- Reset function is changed for 8347 build to allow proper reset of the rack
- 201, 202, 207, 208 - timestamp fixed that there is no longer a need to use all channels for the timestamp to work properly
- 403 - allow input and output to work in ACB mode simultaneously on the same channel
- 566 - always returns even number of words from the layer if timestamp is enabled
- 503 - reset changed to avoid inserting errors into the CAN bus upon chip reset
- 205 - 801 option added (+/-4V without input divider)
- Event is added to output CAN thread to prevent priority inversion situation with free-running thread.
- For AO-3xx layers, SS0OUT is now used as the subsystem for writing output values